Practical Sound Absorption Coefficient (αp)
Edge Thickness Suspension height 125Hz 250Hz 500Hz 1000Hz 2000Hz 4000Hz Class αw NRC
A HAT, A24, C 40mm 40mm 0.25 0.75 1.00 1.00 1.00 1.00 A 1.00 1.00

Sound absorption is measured in accordance with ISO 354.

Sound absorption data αp, αw and absorption class are calculated in accordance with ISO 11654. Sound absorption properties of islands and baffles are quantified by the equivalent sound absorption area Aeq expressed as m² per item.

Back
Sound curve

Product Specifications

Reaction To Fire Reaction To Fire A2-s1,d0 (EN 13501-1)
Reaction to fire is classified in accordance with EN 13501-1.
Light reflection and light diffusion Light reflection and light diffusion White 72% Lightgrey 61% Grey 33% Black 5%
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Humidity And Sag Resistance Humidity And Sag Resistance Up to 100% RH
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Cleaning Cleaning Vacuum
Vacuum: The surface can be vacuum cleaned with a soft brush attachment.
Hygiene Hygiene Stone wool provides no sustenance to microorganisms
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Environment Environment Fully recyclable stone wool
Indoor Environment A selection of Rockfon products have been awarded the Finnish M1 emission classification for building materials and the Danish Indoor Climate Label for low emission products
Impact Resistance Impact Resistance The woven surface of Rockfon VertiQ panels provides enhanced resistance to perforation, tested in accordance with NF P 08-301.,
Back
Reaction to fire is classified in accordance with EN 13501-1.
Back
Light reflection expressed in % is measured in accordance with ISO 7724-2.
Back
ROCKFON ceiling tiles are dimensionally stable even at humidity levels of up to 100% relative humidity and can be installed at all temperatures ranging from 0°C to 40°C. They can be installed during the very early stage of the build (when windows are not fully sealed). Their lightweight yet stable non-hygroscopic character minimises the final weight of the fully-installed ceiling. ROCKFON ceiling tiles are predominantly classified as Class 1/C/0N in accordance with EN 13964. Certain module sizes (width above 700mm) are Class 2/C/0N.
Back
Vacuum: The surface can be vacuum cleaned with a soft brush attachment.
Back
Stone wool provides no sustenance to the following microorganisms tested in accordance with JIS Z 2801:2000 and ASTM C 1338-96: – Escherichia coli – Staphylococcus aureus – Methicillin-resistant staphylococcus aureus (MRSA) – Stachybotrys chartarum – Penicillium brevicumpactum – Alternaria tenuissima – Aspergillus niger – Sporobolomyces roseum – Rhodotorula rubra
Back
Back
Back
Back

Full range

Edge Dimensions (mm) Thickness (mm) Weight (Kg/m2) Min. suspension height (mm) Recommended installation system  
A HAT 1200 x 1200 40 5.20 0 Rockfon® System VertiQ® HAT A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall lining element for acoustic corrections

Sound Absorption

αw 1.00
NRC 1.00
Class A

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
A HAT 2700 x 1200 40 5.20 0 Rockfon® System VertiQ® HAT A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall lining element for acoustic corrections

Sound Absorption

αw 1.00
NRC 1.00
Class A

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
A24 1200 x 1200 40 5.20 0 Rockfon® System VertiQ® T24 A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound Absorption

αw 1.00
NRC 1.00
Class A

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
A24 2700 x 1200 40 5.20 0 Rockfon® System VertiQ® T24 A Wall

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound Absorption

αw 1.00
NRC 1.00
Class A

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
C 2400 x 600 40 6.40 0 Rockfon® System VertiQ® C Wall

Recommended installation system

Concealed wall system Rockfon® System VertiQ® C Wall Wall lining element for acoustic corrections

Sound Absorption

αw 1.00
NRC 1.00
Class A

Tile details

Minimum installation height 0 mm

Packaging

Pieces Per Pack 4
Area Per Pack 5.76 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall lining element for acoustic corrections

Sound Absorption

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® HAT A Wall Wall lining element for acoustic corrections

Sound Absorption

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound Absorption

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 6
Area Per Pack 8.64 m2
Back

Recommended installation system

Visible profile wall system Rockfon® System VertiQ® T24 A Wall Wall lining element for acoustic corrections

Sound Absorption

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 4
Area Per Pack 12.96 m2
Back

Recommended installation system

Concealed wall system Rockfon® System VertiQ® C Wall Wall lining element for acoustic corrections

Sound Absorption

Tile details

Minimum installation height 0 mm
Easy access -

Packaging

Pieces Per Pack 4
Area Per Pack 5.76 m2
Back

Downloads

documents

 

 

pdf
Rockfon® System VertiQ® C Wall | System description
Rockfon® System VertiQ® C Wall | System description

pdf
Rockfon® System VertiQ® HAT A Wall | System description
Rockfon® System VertiQ® HAT A Wall | System description

pdf
pdf
Rockfon® System VertiQ® T24 A Wall | System description
Rockfon® System VertiQ® T24 A Wall | System description

pdf
pdf
Rockfon VertiQ® | Datasheet
Rockfon VertiQ® | Datasheet

pdf
DoP-RFN-0129-041-4 - Rockfon VertiQ®
DoP-RFN-0129-041-4 - Rockfon VertiQ®

pdf
Environmental Product Declaration (EPD)
Environmental Product Declaration (EPD)

pdf
Back